Plasma Copeptin More Accurate for Diabetes Insipidus Diagnosis

Share this content:
Plasma Copeptin More Accurate for Diabetes Insipidus Diagnosis
Plasma Copeptin More Accurate for Diabetes Insipidus Diagnosis

MONDAY, Aug. 6, 2018 (HealthDay News) -- In patients with hypotonic polyuria, the direct measurement of hypertonic saline-stimulated plasma copeptin has better diagnostic accuracy than the water-deprivation test, according to a study published in the Aug. 2 issue of the New England Journal of Medicine.

Wiebke Fenske, M.D., Ph.D., from the University of Leipzig in Germany, and colleagues compared the indirect water-deprivation test with direct detection of plasma copeptin among 144 patients with hypotonic polyuria at 11 medical centers who underwent both tests.

The researchers found that the indirect water-deprivation test determined the correct diagnosis in 108 of the 141 patients included in the analysis (diagnostic accuracy, 76.6 percent), while the hypertonic saline infusion test (with a copeptin cutoff level of >4.9 pmol per liter) determined the correct diagnosis in 136 patients (96.5 percent). Primary polydipsia was distinguished from partial central diabetes insipidus with the indirect water-deprivation test in 77 of 105 patients (73.3 percent), compared to 99 of 104 patients (95.2 percent) with the hypertonic saline infusion. One serious adverse event (desmopressin-induced hyponatremia), which required hospitalization, occurred during the water-deprivation test.

"This prospective evaluation of patients with hypotonic polyuria validated hypertonic saline-stimulated copeptin measurement as a diagnostic method that appeared to be superior to the indirect water-deprivation test in distinguishing central diabetes insipidus from primary polydipsia," the authors write.

Several authors disclosed financial ties to pharmaceutical and medical device companies, including Thermo Fisher Scientific, which funded laboratory measurement of copeptin.

Abstract/Full Text (subscription or payment may be required)
Editorial (subscription or payment may be required)

Share this content:

is free, fast, and customized just for you!




Already a member?

Sign In Now »

Drug Lookup

Browse drugs by: BrandGenericDisease

More in Home

FDA Approves First Customizable Insulin Pump

FDA Approves First Customizable Insulin Pump

Product works by delivering insulin under the skin at set or variable rates

Sepsis Common in Terminal Hospitalizations, Discharges

Sepsis Common in Terminal Hospitalizations, Discharges

Most common underlying causes of death in sepsis are solid and hematologic cancers, chronic heart disease

Fewer Older Men Assessed, Treated for Osteoporosis

Fewer Older Men Assessed, Treated for Osteoporosis

Fewer older men than women, even with higher risk, undergo DXA screening, 25(OH)D measurement

is free, fast, and customized just for you!




Already a member?

Sign In Now »