TUESDAY, Feb. 14, 2017 (HealthDay News) -- Microchannels surrounded by a coagulation zone (CZ), generated by ablative fractional laser, have higher uptake of topical compounds than those without a CZ, according to a study published online Feb. 9 in Lasers in Surgery and Medicine.

Christina Skovbølling Haak, M.D., Ph.D., from the University of Copenhagen in Denmark, and colleagues used Franz Cells to examine skin uptake and permeation of fluorescent labeled polyethylene glycols (PEGs). They generated microchannels with CZ thicknesses ranging from 0 to 80 µm and evaluated skin uptake of PEGs with mean molecular weights of 350, 1,000, and 5,000 Da into CZ and dermis by fluorescence microscopy at skin depths of 150, 400, and 1,000 µm.

The researchers found that uptake of PEGs was highest through microchannels surrounded by CZ versus channels with no CZ. CZ thickness impacted PEG distribution in skin. Significantly higher mean fluorescence intensities inside CZ areas were favored with a thin CZ-20 versus CZ-80 (PEG 350, 1,000, and 5,000; P < 0.001). The uptake through CZ-20 channels was significantly higher in dermis than through CZ-80 and CZ-0 at all skin depths (PEG 350, 1,000, and 5,000; P < 0.001). CZ-20 had the highest transcutaneous permeation of PEG 350 compared with CZ-80 and CZ-0 samples (P < 0.001). Permeation of larger molecules was typically low.

"CZ thickness influences PEG distribution, with highest PEG uptake achieved from microchannels surrounded by a thin CZ," the authors write.

The study was funded in part by a grant from the Novo Nordisk Foundation.

Full Text (subscription or payment may be required)

Share this content:

is free, fast, and customized just for you!




Already a member?

Sign In Now »

Drug Lookup

Browse drugs by: BrandGenericDisease



Sign up for myCME e-newsletters




More in Home

High Success Rates for Mitral Valve Repair With Robotic Surgery

High Success Rates for Mitral Valve Repair With ...

Minimally invasive surgery linked to fewer discharges to facility, one day less in hospital vs conservative sx

Tattoo-Linked Complications ID'd in Immunosuppressed Female

Tattoo-Linked Complications ID'd in Immunosuppressed Female

Inflammatory myopathy identified in woman with cystic fibrosis on long-term immunosuppressants

Rates of Cardiac Stress Testing Down but Still Higher in CKD

Rates of Cardiac Stress Testing Down but Still ...

Decline in rates of cardiac stress testing in Medicare beneficiaries aged ≥66 years from 2008 to 2012

is free, fast, and customized just for you!




Already a member?

Sign In Now »